-->//(Design against Static Load) Example 4.21
-->//Refer Fig.4.68 and 4.65
-->//Load capacity of press P (kN)
-->P = 100
P =
100.
-->//Ultimate tensile strength of FG200 Sut (N/mm2)
-->Sut = 200
Sut =
200.
-->//Factor of safety fs
-->fs = 3
fs =
3.
-->//Distance between force application point and C-Frame centre l (mm)
-->l = 1000
l =
1000.
The value of t = 100.000000 mm
|