-->//(Design against Static Load) Example 4.21 -->//Refer Fig.4.68 and 4.65 -->//Load capacity of press P (kN) -->P = 100 P = 100. -->//Ultimate tensile strength of FG200 Sut (N/mm2) -->Sut = 200 Sut = 200. -->//Factor of safety fs -->fs = 3 fs = 3. -->//Distance between force application point and C-Frame centre l (mm) -->l = 1000 l = 1000. The value of t = 100.000000 mm