+// Calculating the limiting value of specific magnetic loading
+clc;
+disp('Example 6.6, Page No. = 6.12')
+// Given Data
+Bt = 2.0;// Maximum flux density in the armature (in Wb per meter square)
+R = 0.7;// Ratio of pole arc to pole pitch
+Wt_ys = 0.4;// Ratio of minimum width of tooth to slot pitch
+// Calculation of the limiting value of specific magnetic loading
+Bav = R*Wt_ys*Bt;// Limiting value of specific magnetic loading (in W per meter square)
+disp(Bav,'Limiting value of specific magnetic loading (W per meter square)=');
+//in book answer is 0.56 (W per meter square). The answers vary due to round off error