+// A Texbook on POWER SYSTEM ENGINEERING
+// A.Chakrabarti, M.L.Soni, P.V.Gupta, U.S.Bhatnagar
+// DHANPAT RAI & Co.
+// SECOND EDITION
+
+// PART I : GENERATION
+// CHAPTER 3: HYDRO-ELECTRIC STATIONS
+
+// EXAMPLE : 3.3 :
+// Page number 41
+clear ; clc ; close ; // Clear the work space and console
+
+// Given data
+A = 200.0 // Catchment area(Sq.km)
+F = 1000.0 // Annual rainfall(mm)
+H = 200.0 // Effective head(m)
+K = 0.5 // Yield factor
+n = 0.8 // Plant efficiency
+
+// Calculations
+P = 3.14*n*K*A*F*H*10**-4 // Available continuous power(kW)
+
+// Results
+disp("PART I - EXAMPLE : 3.3 : SOLUTION :-")
+printf("\nAvailable continuous power of hydro-electric station , P = %.f kW", P)