diff --git a/431/CH3/EX3.26/EX3_26.sce b/431/CH3/EX3.26/EX3_26.sce new file mode 100755 index 000000000..328225ab7 --- /dev/null +++ b/431/CH3/EX3.26/EX3_26.sce @@ -0,0 +1,23 @@ +//Calculate efficiency of transformer //Chapter 3
+//Example 3.26
+//page 234
+clear;
+clc;
+disp("Example 3.26")
+kVA=400; //rating of the transformer
+ironloss=2; //iron loss in kilowatt
+pf=0.8; //power factor
+kW=240; //load in kilowatt
+kVA1=kW/pf;
+disp("Efficiency is maximium when,core-loss=copper-loss")
+coreloss=ironloss;
+disp("Maximium efficiency occurs at 240kw,0.8 power factor,i.e., at 300kVA load")
+Cl300=coreloss;
+Cl400=(Cl300*(kVA/kVA1)^2);
+pf1=0.71; //power factor for full load
+effi=(kVA*pf1*100)/((kVA*pf1)+coreloss+Cl400);
+printf("\nEfficiency at full-load and 071 power factor=%dpercent",effi);
+pf2=1 //maximium efficiency occurs at unity power factor
+MAXeffi=(kVA1*pf2*100)/((kVA1*pf2)+coreloss+Cl300)
+printf("\nMaximium efficiency at 300kVA and unity power factor=%fpercent",MAXeffi);
+
diff --git a/431/CH3/EX3.26/resultEX3_26.txt b/431/CH3/EX3.26/resultEX3_26.txt new file mode 100755 index 000000000..5a6a1bc51 --- /dev/null +++ b/431/CH3/EX3.26/resultEX3_26.txt @@ -0,0 +1,8 @@ + Example 3.26
+
+ Efficiency is maximium when,core-loss=copper-loss
+
+ Maximium efficiency occurs at 240kw,0.8 power factor,i.e., at 300kVA load
+
+Efficiency at full-load and 071 power factor=98percent
+Maximium efficiency at 300kVA and unity power factor=98.684211percent
\ No newline at end of file |