diff --git a/380/CH4/EX4.10/Ex4_10.sce b/380/CH4/EX4.10/Ex4_10.sce
new file mode 100755
index 000000000..23a14f44d
--- /dev/null
+++ b/380/CH4/EX4.10/Ex4_10.sce
@@ -0,0 +1,41 @@
+//Caption:Find (a) primary winding voltage (b) secondary winding voltage (c) ratio of transformation (d) nominal rating of transformer
+//Exa:4.10
+clc;
+clear;
+close;
+V_1=2400;//in Volts
+V_2=240;//in Volts
+S_o=24*1000;//Volt-Ampere
+I_1=10;//in Amperes
+I_2=100;//in Amperes
+//Refer to fig:4.31 (a)
+V_1a=V_1+V_2;
+V_2a=V_2;
+a_T1=V_1a/V_2a;
+a_T2=V_2a/V_1a;
+a_T3=V_1a/V_1;
+a_T4=V_1/V_1a;
+S_oa_1=V_1a*I_1;
+S_oa_2=V_1a*I_1;
+S_oa_3=V_1a*I_2;
+S_oa_4=V_1a*I_2;
+disp("Refer to fig:4.31a");
+disp(V_1a,'(a) primary winding voltage (in Volts)=');
+disp(V_2a,'(b) secondary winding voltage (in Volts)=');
+disp(a_T1,'(c) ratio of transformation=');
+disp(S_oa_1/1000,'(d) nominal rating of transformer (KVA)=');
+disp("Refer to fig:4.31b");
+disp(V_2a,'(a) primary winding voltage (in Volts)=');
+disp(V_1a,'(b) secondary winding voltage (in Volts)=');
+disp(a_T2,'(c) ratio of transformation=');
+disp(S_oa_2/1000,'(d) nominal rating of transformer (KVA)=');
+disp("Refer to fig:4.31c");
+disp(V_1a,'(a) primary winding voltage (in Volts)=');
+disp(V_1,'(b) secondary winding voltage (in Volts)=');
+disp(a_T3,'(c) ratio of transformation=');
+disp(S_oa_3/1000,'(d) nominal rating of transformer (KVA)=');
+disp("Refer to fig:4.31d");
+disp(V_1,'(a) primary winding voltage (in Volts)=');
+disp(V_1a,'(b) secondary winding voltage (in Volts)=');
+disp(a_T4,'(c) ratio of transformation=');
+disp(S_oa_4/1000,'(d) nominal rating of transformer (KVA)='); \ No newline at end of file