summaryrefslogtreecommitdiff
path: root/usrp2/fpga/control_lib/clock_control.v
diff options
context:
space:
mode:
Diffstat (limited to 'usrp2/fpga/control_lib/clock_control.v')
-rw-r--r--usrp2/fpga/control_lib/clock_control.v115
1 files changed, 115 insertions, 0 deletions
diff --git a/usrp2/fpga/control_lib/clock_control.v b/usrp2/fpga/control_lib/clock_control.v
new file mode 100644
index 000000000..1bbe6bd75
--- /dev/null
+++ b/usrp2/fpga/control_lib/clock_control.v
@@ -0,0 +1,115 @@
+
+
+// AD9510 Register Map (from datasheet Rev. A)
+
+/* INSTRUCTION word format (16 bits)
+ * 15 Read = 1, Write = 0
+ * 14:13 W1/W0, Number of bytes 00 - 1, 01 - 2, 10 - 3, 11 - stream
+ * 12:0 Address
+ */
+
+/* ADDR Contents Value (hex)
+ * 00 Serial Config Port 10 (def) -- MSB first, SDI/SDO separate
+ * 04 A Counter
+ * 05-06 B Counter
+ * 07-0A PLL Control
+ * 0B-0C R Divider
+ * 0D PLL Control
+ * 34-3A Fine Delay
+ * 3C-3F LVPECL Outs
+ * 40-43 LVDS/CMOS Outs
+ * 45 Clock select, power down
+ * 48-57 Dividers
+ * 58 Func and Sync
+ * 5A Update regs
+ */
+
+
+module clock_control
+ (input reset,
+ input aux_clk, // 25MHz, for before fpga clock is active
+ input clk_fpga, // real 100 MHz FPGA clock
+ output [1:0] clk_en, // controls source of reference clock
+ output [1:0] clk_sel, // controls source of reference clock
+ input clk_func, // FIXME needs to be some kind of out SYNC or reset to 9510
+ input clk_status, // Monitor PLL or SYNC status
+
+ output sen, // Enable for the AD9510
+ output sclk, // FIXME these need to be shared
+ input sdi,
+ output sdo
+ );
+
+ wire read = 1'b0; // Always write for now
+ wire [1:0] w = 2'b00; // Always send 1 byte at a time
+
+ assign clk_sel = 2'b00; // Both outputs from External Ref (SMA)
+ assign clk_en = 2'b11; // Both outputs enabled
+
+ reg [20:0] addr_data;
+
+ reg [5:0] entry;
+ reg start;
+ reg [7:0] counter;
+ reg [23:0] command;
+
+ always @*
+ case(entry)
+ 6'd00 : addr_data = {13'h00,8'h10}; // Serial setup
+ 6'd01 : addr_data = {13'h45,8'h00}; // CLK2 drives distribution, everything on
+ 6'd02 : addr_data = {13'h3D,8'h80}; // Turn on output 1, normal levels
+ 6'd03 : addr_data = {13'h4B,8'h80}; // Bypass divider 1 (div by 1)
+ 6'd04 : addr_data = {13'h08,8'h47}; // POS PFD, Dig LK Det, Charge Pump normal
+ 6'd05 : addr_data = {13'h09,8'h70}; // Max Charge Pump current
+ 6'd06 : addr_data = {13'h0A,8'h04}; // Normal operation, Prescalar Div by 2, PLL On
+ 6'd07 : addr_data = {13'h0B,8'h00}; // RDIV MSB (6 bits)
+ 6'd08 : addr_data = {13'h0C,8'h01}; // RDIV LSB (8 bits), Div by 1
+ 6'd09 : addr_data = {13'h0D,8'h00}; // Everything normal, Dig Lock Det
+ 6'd10 : addr_data = {13'h07,8'h00}; // Disable LOR detect - LOR causes failure...
+ 6'd11 : addr_data = {13'h04,8'h00}; // A Counter = Don't Care
+ 6'd12 : addr_data = {13'h05,8'h00}; // B Counter MSB = 0
+ 6'd13 : addr_data = {13'h06,8'h05}; // B Counter LSB = 5
+ default : addr_data = {13'h5A,8'h01}; // Register Update
+ endcase // case(entry)
+
+ wire [5:0] lastentry = 6'd15;
+ wire done = (counter == 8'd49);
+
+ always @(posedge aux_clk)
+ if(reset)
+ begin
+ entry <= #1 6'd0;
+ start <= #1 1'b1;
+ end
+ else if(start)
+ start <= #1 1'b0;
+ else if(done && (entry<lastentry))
+ begin
+ entry <= #1 entry + 6'd1;
+ start <= #1 1'b1;
+ end
+
+ always @(posedge aux_clk)
+ if(reset)
+ begin
+ counter <= #1 7'd0;
+ command <= #1 20'd0;
+ end
+ else if(start)
+ begin
+ counter <= #1 7'd1;
+ command <= #1 {read,w,addr_data};
+ end
+ else if( |counter && ~done )
+ begin
+ counter <= #1 counter + 7'd1;
+ if(~counter[0])
+ command <= {command[22:0],1'b0};
+ end
+
+
+ assign sen = (done | counter == 8'd0); // CSB is high when we're not doing anything
+ assign sclk = ~counter[0];
+ assign sdo = command[23];
+
+endmodule // clock_control