summaryrefslogtreecommitdiff
path: root/scan.ads
blob: 28100aa0c6e040ba25aa077fc1ae754cd871b41a (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
--  VHDL lexical scanner.
--  Copyright (C) 2002, 2003, 2004, 2005 Tristan Gingold
--
--  GHDL is free software; you can redistribute it and/or modify it under
--  the terms of the GNU General Public License as published by the Free
--  Software Foundation; either version 2, or (at your option) any later
--  version.
--
--  GHDL is distributed in the hope that it will be useful, but WITHOUT ANY
--  WARRANTY; without even the implied warranty of MERCHANTABILITY or
--  FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License
--  for more details.
--
--  You should have received a copy of the GNU General Public License
--  along with GCC; see the file COPYING.  If not, write to the Free
--  Software Foundation, 59 Temple Place - Suite 330, Boston, MA
--  02111-1307, USA.
with Types; use Types;
with Tokens; use Tokens;

package Scan is
   -- Global variables
   -- The token that was just scanned.
   -- When the token was eaten, you can call invalidate_current_token to
   -- set it to tok_invalid.
   -- Current_token should not be written outside of scan package.
   -- It can be replaced by a function call.
   Current_Token: Token_Type := Tok_Invalid;

   -- Simply set current_token to tok_invalid.
   procedure Invalidate_Current_Token;
   pragma Inline (Invalidate_Current_Token);

   -- When CURRENT_TOKEN is an tok_identifier, tok_char or tok_string,
   -- its name_id can be got via this function.
   function Current_Identifier return Name_Id;
   pragma Inline (Current_Identifier);

   -- Get current string identifier and length.
   function Current_String_Id return String_Id;
   function Current_String_Length return Nat32;
   pragma Inline (Current_String_Id);
   pragma Inline (Current_String_Length);

   -- Set Current_identifier to null_identifier.
   -- Can be used to catch bugs.
   procedure Invalidate_Current_Identifier;
   pragma Inline (Invalidate_Current_Identifier);

   -- When CURRENT_TOKEN is tok_integer, returns the value.
   -- When CURRENT_TOKEN is tok_bit_string, returns the base.
   function Current_Iir_Int64 return Iir_Int64;
   pragma Inline (Current_Iir_Int64);

   -- When CURRENT_TOKEN is tok_real, it returns the value.
   function Current_Iir_Fp64 return Iir_Fp64;
   pragma Inline (Current_Iir_Fp64);

   -- Advances the lexical analyser.  Put a new token into current_token.
   procedure Scan;

   -- Initialize the scanner with file SOURCE_FILE.
   procedure Set_File (Source_File : Source_File_Entry);

   procedure Set_Current_Position (Position: Source_Ptr);

   -- Finalize the scanner.
   procedure Close_File;

   --  If true, comments are reported as a token.
   Flag_Comment : Boolean := False;

   --  If true, newlines are reported as a token.
   Flag_Newline : Boolean := False;

   -- Get the current location, or the location of the current token.
   -- Since a token cannot spread over lines, file and line of the current
   -- token are the same as those of the current position.
   function Get_Current_File return Name_Id;
   function Get_Current_Source_File return Source_File_Entry;
   function Get_Current_Line return Natural;
   function Get_Current_Column return Natural;
   function Get_Token_Location return Location_Type;
   function Get_Token_Column return Natural;
   function Get_Token_Position return Source_Ptr;
   function Get_Position return Source_Ptr;

   --  Convert (canonicalize) an identifier stored in name_buffer/name_length.
   --  Upper case letters are converted into lower case.
   --  Lexical checks are performed.
   --  This procedure is not used by Scan, but should be used for identifiers
   --  given in the command line.
   --  Errors are directly reported through error_msg_option.
   --  Also, Vhdl_Std should be set.
   procedure Convert_Identifier;

end Scan;