diff options
author | Tristan Gingold | 2013-12-20 04:48:54 +0100 |
---|---|---|
committer | Tristan Gingold | 2013-12-20 04:48:54 +0100 |
commit | 6c3f709174e8e4d5411f851cedb7d84c38d3b04a (patch) | |
tree | bd12c79c71a2ee65899a9ade9919ec2045addef8 /testsuite/vests/vhdl-ams/ashenden/compliant/aliases/safety_switch.vhd | |
parent | bd4aff0f670351c0652cf24e9b04361dc0e3a01c (diff) | |
download | ghdl-6c3f709174e8e4d5411f851cedb7d84c38d3b04a.tar.gz ghdl-6c3f709174e8e4d5411f851cedb7d84c38d3b04a.tar.bz2 ghdl-6c3f709174e8e4d5411f851cedb7d84c38d3b04a.zip |
Import vests testsuite
Diffstat (limited to 'testsuite/vests/vhdl-ams/ashenden/compliant/aliases/safety_switch.vhd')
-rw-r--r-- | testsuite/vests/vhdl-ams/ashenden/compliant/aliases/safety_switch.vhd | 43 |
1 files changed, 43 insertions, 0 deletions
diff --git a/testsuite/vests/vhdl-ams/ashenden/compliant/aliases/safety_switch.vhd b/testsuite/vests/vhdl-ams/ashenden/compliant/aliases/safety_switch.vhd new file mode 100644 index 0000000..fb3caad --- /dev/null +++ b/testsuite/vests/vhdl-ams/ashenden/compliant/aliases/safety_switch.vhd @@ -0,0 +1,43 @@ + +-- Copyright (C) 2002 Morgan Kaufmann Publishers, Inc + +-- This file is part of VESTs (Vhdl tESTs). + +-- VESTs is free software; you can redistribute it and/or modify it +-- under the terms of the GNU General Public License as published by the +-- Free Software Foundation; either version 2 of the License, or (at +-- your option) any later version. + +-- VESTs is distributed in the hope that it will be useful, but WITHOUT +-- ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or +-- FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License +-- for more details. + +-- You should have received a copy of the GNU General Public License +-- along with VESTs; if not, write to the Free Software Foundation, +-- Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA + +library ieee_proposed; +use ieee_proposed.electrical_systems.all, ieee_proposed.mechanical_systems.all; + +entity safety_switch is + port ( terminal neutral : electrical; + terminal relay_actuator : translational ); +end entity safety_switch; + +-- code from book + +library ieee_proposed; +use ieee_proposed.electrical_systems.all, ieee_proposed.mechanical_systems.all; + +architecture basic of safety_switch is + + quantity neutral_potential across neutral to ground; + quantity relay_position across relay_actuator to anchor; + -- ... + +begin + -- ... +end architecture basic; + +-- end code from book |