@@ -0,0 +1,34 @@
+
+// ELECTRICAL MACHINES
+// R.K.Srivastava
+// First Impression 2011
+// CENGAGE LEARNING INDIA PVT. LTD
+
+// CHAPTER : 6 : SYNCHRONOUS MACHINES
+
+// EXAMPLE : 6.30
+
+clear ; clc ; close ; // Clear the work space and console
+
+
+// GIVEN DATA
+
+f = 50; // Operating Frequency of the Synchronous generator in Hertz
+p = 2; // Number of the poles
+Pt = 800; // Total loss in Watts
+Pr = 10; // Rotational loss in Watts
+
+
+// CALCULATIONS
+
+Ws = (4*%pi*f)/p; // Synchronous speed in radians/s
+Ph = Pt-Pr; // Hysteresis loss refered to stator in Watts
+Th = Ph/Ws; // Torque at the shaft in Newton-meter
+
+
+// DISPLAY RESULTS
+
+disp("EXAMPLE : 6.30: SOLUTION :-");
+printf("\n (a) Power at the shaft, Ph = %.f W \n",Ph)
+printf("\n )b) Torque at the shaft , Th = %.2f N-m \n",Th)
+