diff options
author | Siddharth Agarwal | 2019-09-03 18:27:40 +0530 |
---|---|---|
committer | Siddharth Agarwal | 2019-09-03 18:27:40 +0530 |
commit | 8ac15bc5efafa2afc053c293152605b0e6ae60ff (patch) | |
tree | e1bc17aae137922b1ee990f17aae4a6cb15b7d87 /Working_Examples/83/CH5/EX5.2 | |
parent | 52a477ec613900885e29c4a0b02806a415b4f83a (diff) | |
download | Xcos_block_examples-8ac15bc5efafa2afc053c293152605b0e6ae60ff.tar.gz Xcos_block_examples-8ac15bc5efafa2afc053c293152605b0e6ae60ff.tar.bz2 Xcos_block_examples-8ac15bc5efafa2afc053c293152605b0e6ae60ff.zip |
Diffstat (limited to 'Working_Examples/83/CH5/EX5.2')
-rwxr-xr-x | Working_Examples/83/CH5/EX5.2/example_5_2.sce | 28 | ||||
-rwxr-xr-x | Working_Examples/83/CH5/EX5.2/result_example_5_2.txt | 10 |
2 files changed, 38 insertions, 0 deletions
diff --git a/Working_Examples/83/CH5/EX5.2/example_5_2.sce b/Working_Examples/83/CH5/EX5.2/example_5_2.sce new file mode 100755 index 0000000..925e68d --- /dev/null +++ b/Working_Examples/83/CH5/EX5.2/example_5_2.sce @@ -0,0 +1,28 @@ +//Chapter 5 +//Example 5.2 +//page 134 +//To find voltage at the bus at the power station end +clc;clear; + +base_MVA=5; +base_kV=33; +pf=0.85; +cable_impedance=(8+%i*2.5); +cable_impedance=cable_impedance*base_MVA/(base_kV^2); + +transf_imp_star=(0.06+%i*0.36)/3; //equivalent star impedance of winding of the transformer +Zt=(transf_imp_star*5/(6.6^2))+((0.5+%i*3.75)*5/(33^2)); +total=cable_impedance+2*Zt; + +load_MVA=1; +load_voltage=6/6.6; +load_current=1/load_voltage; + +Vs=load_voltage+load_current*(real(total)*pf+imag(total)*sin(acos(pf))); +Vs=Vs*6.6; +printf('\n\nCable impedance= (%0.3f+j%0.4f) pu\n',real(cable_impedance),imag(cable_impedance)); +printf('\nEquivalent star impedance of 6.6kV winding of the transformer =(%0.2f+j%0.2f) pu\n',real(transf_imp_star),imag(transf_imp_star)); +printf('\nPer unit transformer impedance,Zt=(%0.4f+j%0.3f) pu\n',real(Zt),imag(Zt)); +printf('\nTotal series impedance=(%0.3f+j%0.3f) pu\n',real(total),imag(total)); +printf('\nSending end Voltage =|Vs|=%0.2fkV (line-to-line)',Vs); + diff --git a/Working_Examples/83/CH5/EX5.2/result_example_5_2.txt b/Working_Examples/83/CH5/EX5.2/result_example_5_2.txt new file mode 100755 index 0000000..f9b1d06 --- /dev/null +++ b/Working_Examples/83/CH5/EX5.2/result_example_5_2.txt @@ -0,0 +1,10 @@ + +Cable impedance= (0.037+j0.0115) pu + +Equivalent star impedance of 6.6kV winding of the transformer =(0.02+j0.12) pu + +Per unit transformer impedance,Zt=(0.0046+j0.031) pu + +Total series impedance=(0.046+j0.073) pu + +Sending end Voltage =|Vs|=6.56kV (line-to-line) |