-->//(Threaded Joints) Example 7.4
-->//Refer Fig.7.19 on page 235
-->//Force acting on the steel plate P (kN)
-->P = 5
P =
5.
-->//Yield tensile strength of 45C8 Syt (N/mm2)
-->Syt = 380
Syt =
380.
-->//Factor of safety fs
-->fs = 3
fs =
3.
-->//Number of bolts N
-->N = 3
N =
3.
-->//Eccentricity value (distance between C.G. of bolts and force) e (mm)
-->e = 200 + 30 + 75
e =
305.
-->//Distance between bolt1 and bolt2 r1 (mm)
-->r1 = 75
r1 =
75.
-->//Distance between bolt2 and bolt3 r3 (mm)
-->r3 = 75
r3 =
75.
The standard size of the bolts is M20
|