blob: 945b162fec43f2ae11e6cd7d98a76a6cc7940930 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
|
-->//(Design against Static Load) Example 4.8
-->//Refer Fig.4.27
-->//Force acting on offset link P (kN)
-->P = 25
P =
25.
-->//Ultimate tensile strength of FG300 Sut (N/mm2)
-->Sut = 300
Sut =
300.
-->//Factor of safety (fs)
-->fs = 3
fs =
3.
-->//Force offset distance e (mm)
-->e = 10
e =
10.
-->//Ratio of depth to width of the cross-section ratio
-->ratio = 2
ratio =
2.
Value of t = 25.443742 mm
Area of cross-section = (25.443742 x 50.887483) mm2
|