-->//(Design against Static Load) Example 4.8
 
-->//Refer Fig.4.27
 
-->//Force acting on offset link P (kN)
 
-->P = 25
 P  =
 
    25.  
 
-->//Ultimate tensile strength of FG300 Sut (N/mm2)
 
-->Sut = 300
 Sut  =
 
    300.  
 
-->//Factor of safety (fs)
 
-->fs = 3
 fs  =
 
    3.  
 
-->//Force offset distance e (mm)
 
-->e = 10
 e  =
 
    10.  
 
-->//Ratio of depth to width of the cross-section ratio
 
-->ratio = 2
 ratio  =
 
    2.  
 
 

Value of t = 25.443742 mm

Area of cross-section = (25.443742 x 50.887483) mm2