11

//(Design against Static Load) Example 4.21
//Refer Fig.4.68 and 4.65
//Load capacity of press P (kN)
P = 100
//Ultimate tensile strength of FG200 Sut (N/mm2)
Sut = 200
//Factor of safety fs
fs = 3
//Distance between force application point and C-Frame centre l (mm)
l = 1000