-->//(Design against Static Load) Example 4.2
 
-->//Refer section 4.10 on page 90
 
-->//Axial tensile force acting on acting on each rod P (kN)
 
-->P = 50
 P  =
 
    50.  
 
-->//Tensile yield strength of the material Syt (N/mm2)
 
-->Syt = 400
 Syt  =
 
    400.  
 
-->//Factor of safety for rod f1
 
-->f1 = 6
 f1  =
 
    6.  
 
-->//Factor of safety for cotter f2
 
-->f2 = 4
 f2  =
 
    4.  
 

Diameter of the rods(d) = 31.000000 mm

Thickness of cotter(t) = 10.000000 mm

Diameter of spigot(d2) = 40.000000 mm

Outer diameter of socket(d1) = 55.000000 mm

Diameter of spigot collar(d3) = 47.000000 mm

Diameter of socket collar(d4) = 80.000000 mm

Width of cotter(b) = 50.000000 mm

Thickness of spigot collar(t1) = 15.000000 mm

Design of cotter joint is safe