//(Design against Static Load) Example 4.14
//Refer Fig.4.41
//Force acting on the overhang crank P (kN)
P = 1
//Tensile yield strength of 30C8 material Syt (N/mm2)
Syt = 400
//Factor of safety fs
fs = 2
//Horizontal distance between the point load and D h (mm)
h = 500
//Vertical distance between the point load and D v (mm)
v = 50 + 25 + 100