blob: 04d25e150739adae62ff4ada742ecde213dfa89b (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
|
clc();
clear;
// To calculate the net radiant interchange per foot length of pipe of 2 in. standard diameter
e=0.8; // emmisivity of pipe metal
D=2.375/12; // Diameter of pipe in ft
s=0.174; // Stephans Boltzman's constant
T1=(300+460)/100; // Temperature of disc 1 in degF
T2=(80+460)/100; // Temperature of disc 2 in degF
A1=%pi*D; // Area of one foot of pipe in ft^2
q12=s*e*A1*((T1^4)-(T2^4)); // Radiant interchange in Btu/hr
printf("The net radiant interchange per foot length of pipe is %.1f Btu/hr-ft",q12);
|