summaryrefslogtreecommitdiff
path: root/431/CH3/EX3.22/resultEX3_22.txt
blob: 254ef0634e538df6055f8addc63d8e706f1be7bc (plain)
1
2
3
4
5
6
7
  
 Example 3.22   

Core loss of two transformer=3.400000kW
Core loss of each transformer=1.700000kW
Full load copper loss of the two transformer=5.200000kWTherefore,full load copper loss of each transformer=2.600000kW
Full load efficiency at 0.8 p.f. lagging=97.382836percent