Example 3.22
Core loss of two transformer=3.400000kW
Core loss of each transformer=1.700000kW
Full load copper loss of the two transformer=5.200000kWTherefore,full load copper loss of each transformer=2.600000kW
Full load efficiency at 0.8 p.f. lagging=97.382836percent
|