example 15.6
energy needed o pump water every day 3.406250kWh/day
overall efficiency 0.34
energy output of pv system 10kWh/day
annual energy out of array 10Wh/Wp
daily energy output of array 5.479Wh/Wp
peak wattage of pv array 1825.00Wp
rms output voltage 222.14V
number of modules in series 13
rated peak power output of each string 520.00W
number of strings in parallel 4
|