//chapter 10 example 3
clc;
clear all;
//variable declaration
V = 120; //voltage in V
I = 8; //current in A
RA = 0.3; //resistance in Ω
AR = 0.01; //maximum reading of ammeter in A
VR = 0.1; //maximum reading of voltmeter in V
AR1 = 10; //ammeter rane 0-10 A
AV1 = 150; //voltmeter range in 0-150 V
EA = 0.25; //constructional error of ammeter in %
EV = 0.5; //constructional error of voltmeter in %
//calculations
Rm = V/I; //measured value of unknown resistance in Ω
Rx = Rm-RA; //true value of unknown resistance in Ω
EA1 = (AR/AR1)*100; //reading error of ammeter in %
EV1 = (VR/AV1)*100; //reading of voltmeter in %
dI = EA+EA1; //error in ammeter reading in %
dv = EV+EV1; //error in voltmeter reading in %
d =dI+dv; //total error in % ranging - to +
R1 = Rx+d; //Value of Rx is specified as Ω
R2 = Rx-d; //Value of Rx is specified as Ω
//result
mprintf("Value of Rx is specified = %3.3f,%3.3f Ω",R1,R2);
|