blob: b62b645216bbcc4edec26b016f9027ded6072c2d (
plain)
1
2
3
4
5
6
7
8
9
10
11
|
clc;
vdr=2; // percentage full load voltage drop in resistance
vdx=4; // percentage full load voltage drop in leakage reactance
// full load ohmic losses are equal to 0.02*VA rating of transformer which is equal to iron losses
n=100/(1+(vdr/100)+(vdr/100));
printf('Efficiency on full load at unity p.f is %f percent\n',n);
// maximum voltage drop means voltage regulation is also maximum
pf=vdr/sqrt(vdr^2+vdx^2);
printf('Full load power factor at which voltage regulation is maximum is %f lagging\n',pf);
pf=vdx/sqrt(vdr^2+vdx^2);
printf(' load power factor at which voltage regulation is zero is %f leading',pf);
|