Example 17.3
When divergent section act as a nozzle
Maximum flow rate of air is 1.064764 kg/s
Static temperature is 183.204000 K
Static Pressure is 93.900000 kPa
Velocity at the exit from the nozzle is 596.077184 m/s
When divergent section act as a diffuser
Maximum flow rate of air is 1.064764 kg/s
Static temperature is 353.232000 K
Static Pressure is 936 kPa
Velocity at the exit from the nozzle is 116 m/s
|