 Example 12.5

 Efficiency of the cycle is 36.068757 percent
 Steam rate of the cycle is 3.852647 kg/kW h
 Increase in temperature due to regeneration is 27.386207 degree centigrade
 Increase in steam rate due to regeneration is 0.385518 kg/kW h
 Increase in Efficiency of the cycle due to regeneration is 1.902940 percent