11
|
//Example 4.7
clc;
Ifsd=200*10^-6; //Full Scale Current
S=1/Ifsd; //Sensitivity
disp(S,'Sensitivity of 200 uA meter')
V=50; //Full range voltage of the instrument
Rm=100; //Internal resistance of movement
Rs=S*V-Rm; //Multiplier resistence
disp(Rs,'Value of Multipliier Resistence')
|