//Example 4.4
clc;
Im=10*10^-3; //Full Scale Deflection Current
Rm=500; //Internal resistance of movement
//Case I: For Range 0-20 V
V=20; //Full range voltage of the instrument
Rs=V/Im-Rm; //Multiplier resistence
disp(Rs,'Value of Multipliier Resistence 0-20 V')
//Case II: For Range 0-50 V
V=50; //Full range voltage of the instrument
Rs=V/Im-Rm; //Multiplier resistence
disp(Rs,'Value of Multipliier Resistence for 0-50 V')
//Case III: For Range 0-100 V
V=100; //Full range voltage of the instrument
Rs=V/Im-Rm; //Multiplier resistence
disp(Rs,'Value of Multipliier Resistence for 0-100 V')
|