//CHAPTER 8- DIRECT CURRENT MACHINES
//Example 35
disp("CHAPTER 8");
disp("EXAMPLE 35");
//VARIABLE INITIALIZATION
r_a=0.06; //armature resistance in Ohms
r_se=0.04; //series resistance in Ohms
r_sh=25; //shunt resistance in Ohms
v_t=110; //in Volts
I_l=100; //in Amperes
//SOLUTION
//solution (a)
I_sh=v_t/r_sh;
I_a=I_l-I_sh;
E_g=v_t-I_a*(r_a+r_se);
disp("(a) When the machine is connected as long shunt compound generator-");
disp(sprintf("The armature current is %f A and the total emf is %f V",I_a,E_g));
//solution (b)
I_sh=(v_t/r_sh)-(I_l*r_se/r_sh);
I_a=I_l-I_sh;
E_g=v_t-(I_a*r_a)-(I_l*r_se);
disp("(b) When the machine is connected as short shunt compound generator-");
disp(sprintf("The armature current is %f A and the total emf is %f V",I_a,E_g));
//END
|