summaryrefslogtreecommitdiff
path: root/965/CH4/EX4.2
diff options
context:
space:
mode:
Diffstat (limited to '965/CH4/EX4.2')
-rw-r--r--965/CH4/EX4.2/2.sci22
1 files changed, 22 insertions, 0 deletions
diff --git a/965/CH4/EX4.2/2.sci b/965/CH4/EX4.2/2.sci
new file mode 100644
index 000000000..b55742fda
--- /dev/null
+++ b/965/CH4/EX4.2/2.sci
@@ -0,0 +1,22 @@
+clc;
+clear all;
+disp("required time calculation")
+As=2*0.4*0.4;// m^2 surface area of plate
+V=0.4*0.4*4/1000;// m^3 volume of plate
+Lc=V/As;// m characteristic length of plate
+h=20000;//kJ/m^2.h.C
+k=370;//W/m.C
+rho=3000;// kg/m^3
+C=0.8;//kJ/kg.C
+t=-70;// degree C
+ta=-183;// degree C
+ti=200;// degree C
+Bi=h*Lc/k;// biot number
+if (Bi< 0.1)
+disp("Bi is less than 0.1 hence lumped heat capacity method can be applied")
+end
+disp("Temperature distribution is given by : (t-ta)/(ti-ta) = exp((-h*As*tau)/rho*V*C)")
+m= (t-ta)/(ti-ta);
+x=-h/(Lc*rho*C);
+tau=3600*(log(m))/x;
+disp("sec",tau,"time required to attend the temperature is ")