+(a)First finding various dimensions:
+ Torque Mt=88 Nm
+ diameter of pinion=138.46 mm
+ Slant height of pitch cone=121.63 mm
+ Mean radius of pinion=57.85 mm
+
+(b) Finding various forces:
+Tangential force at mean radius=1523.81 N
+
+Pinion thrust force=224.32 N
+