diff --git a/632/CH8/EX8.17/example8_17.sce b/632/CH8/EX8.17/example8_17.sce new file mode 100755 index 000000000..cb36a6a2e --- /dev/null +++ b/632/CH8/EX8.17/example8_17.sce @@ -0,0 +1,31 @@ +//clc()
+Tin = 380.7;//K
+Pin = 101.3;//kPa
+Tdew = 298;//K
+mremoved = 2.25;//kg
+V = 100;//m^3
+//using humidity chart, humidity of air at dry bulb temperature of 380.7K and dew point = 298K is,
+Y = 0.02;// kg water /kg dry air
+disp("kg water /kg dry air",Y,"(a)Humidity of air entering the drier = ")
+Tstp = 273.15;//K
+Vstp = 22.4143;//m^3/kmol
+N = V * Tstp / ( Vstp * Tin );
+MY = Y * 29 / 18;//molal humidity
+Ndryair = N / ( 1 + MY );
+mdryair = Ndryair *29;
+mwaterin = mdryair * Y;
+mwaterout = mwaterin + mremoved;
+Yout = mwaterout / mdryair;
+// percent humidity is calculated using the chart, and is
+PY = 55;//%
+disp("kg water /kg dry air",Yout,"(b)exit air humidity = ")
+disp("%",PY,"Percent humidity = ")
+//from the humidity chart
+Twet = 313.2;//K
+Td = 322.2;//K
+disp("K",Twet,"(c)exit air wet bulb temperature = ")
+disp("K",Td,"(c)exit air dry bulb temperature = ")
+MYout = Yout * 29 / 18;
+Nout = Ndryair * ( 1 + MYout ) / 1;
+V1 = Nout * Vstp * Td / Tstp;
+disp("m^3",V1,"(d)Volume of exit air = ")
\ No newline at end of file |