diff --git a/587/CH11/EX11.6/example11_6.sce b/587/CH11/EX11.6/example11_6.sce new file mode 100755 index 000000000..2169148dc --- /dev/null +++ b/587/CH11/EX11.6/example11_6.sce @@ -0,0 +1,22 @@ +clear;
+clc;
+
+//Example11.6[Cooling of Water in an Automotive Radiator]
+//Given:-
+m=0.6;//Mass Flow rate of water[kg/s]
+Th_in=90,Th_out=65,Tc_in=20,Tc_out=40;//[degree Celcius]
+Di=0.005;//[m]
+L=0.65;//[m]
+n=40;//No of tubes
+Cp=4195;//[J/kg.degree Celcius]
+//Solution:-
+Q=m*Cp*(Th_in-Th_out);//[W]
+disp("W",Q,"The rate of heat transfer in the radiator from the hot water to the air is")
+Ai=n*%pi*Di*L;//[m^2]
+del_T1=Th_in-Tc_out;//[degree Celcius]
+del_T2=Th_out-Tc_in;//[degree Celcius]
+del_T_lm=(del_T1-del_T2)/log(del_T1/del_T2);//[degree Celcius]
+disp("degree Celcius",del_T_lm,"The log mean temperature difference for the counter flow arrangement is")