diff --git a/3888/CH14/EX14.4/Ex14_4.sce b/3888/CH14/EX14.4/Ex14_4.sce new file mode 100644 index 000000000..b11406f6a --- /dev/null +++ b/3888/CH14/EX14.4/Ex14_4.sce @@ -0,0 +1,24 @@ +//Electric Power Generation, Transmission and Distribution by S.N.Singh
+//Publisher:PHI Learning Private Limited
+//Year: 2012 ; Edition - 2
+//Example 14.4
+//Scilab Version : 6.0.0 ; OS : Windows
+
+clc;
+clear;
+
+
+f=50; //Supply frequency in Hz
+I=150; //Power line current in Amps
+dac=1.8; //Spacing between conductors a and d in m
+dab=2.5; //Spacing between conductors a and b in m
+dcd=1; //Spacing between conductors c and d in m
+Dad=sqrt((dac)^(2)+((dab/2)+(dcd/2))^(2)); //Distance between conductors a and d in m
+Dac=sqrt((dac)^(2)+((dab/2)-(dcd/2))^(2)); //Distance between conductors a and c in m
+M=4*10^(-4)*log(Dad/Dac); //Mutual inductance in H/km/ph
+X=2*%pi*f*M; //Inductive reactance in per km
+emf=I*X; //Emf induced in telephone line in V/km
+
+printf("\nThe mutual inductance between the powerline and the telephone line %.1e H/km/ph",M);
+printf("\nThe 50 Hz voltage per kilometre induced in the telephone line when the power line carries 150 A is %.2f V/km",emf);
+
|