diff options
Diffstat (limited to '3872/CH4/EX4.6/Ex4_6.sce')
-rw-r--r-- | 3872/CH4/EX4.6/Ex4_6.sce | 25 |
1 files changed, 25 insertions, 0 deletions
diff --git a/3872/CH4/EX4.6/Ex4_6.sce b/3872/CH4/EX4.6/Ex4_6.sce new file mode 100644 index 000000000..967192616 --- /dev/null +++ b/3872/CH4/EX4.6/Ex4_6.sce @@ -0,0 +1,25 @@ +// Book - Power System: Analysis & Design 5th Edition
+// Authors - J. Duncan Glover, Mulukutla S. Sharma, Thomas J. Overbye
+// Chapter - 4 : Example 4.6
+// Scilab Version 6.0.0 : OS - Windows
+
+
+clc;
+clear;
+
+V = 20; // Line Voltage in kV
+D = 0.552; // Diameter of a 4/0 12 strand copper conductor From Table A.3
+f = 60; // Frequency Hz
+
+
+r = (D/2)*(1/12); // The radius of a 4/0 12 strand copper conductor From Table A.3
+e = 8.854*10^-12;
+C = (%pi*e)/log(5/r);
+Cxy = C*1609*20; // Capacitance between Conductors in F/m
+w = (2*%pi*f); // Angular Velocity in rad/sec
+Yxy = (%i)*(w)*(Cxy); // Shunt Admitance Siemens
+Qc = abs(Yxy)*(20*10^3)^2*(1/1000); // Reactive Power Delivered by the linw to line capacitance in kVAR
+
+
+printf('Capacitance between Conductors is (Cxy) = %0.2e F', Cxy);
+printf('\nReactive Power Delivered by the line to line capacitance is (Qc) = %0.1f kVAR', Qc);
|