+//Book - Power system: Analysisi & Design 5th Edition
+//Authors - J. Duncan Glover, Mulukutla S. Sarma, and Thomas J.Overbye
+//Chapter-11 ;Example 11.10
+//Scilab Version - 6.0.0; OS - Windows
+
+clc;
+clear;
+
+P=1.0 //Infinite bus received real power in per unit
+Vbus=1.0 //Infinite bus voltage in per unit
+Vr=1.0 //system voltage in per unit
+pf=0.95 //Lagging power factor
+Ra=0 //Machine resistance in per unit
+Xd=2.1 //direct axis reactance in per unit
+Xq=2.0 //qadrature axis reactance in per unit
+Xdt=0.3 //direct axis transient reactance in per unit
+Xqt=0.5 //qadrature axis transient reactance in per unit
+X=%i*0.22
+
+theta=acos(pf);
+I=(P/(Vbus*pf))*exp(-%i*theta); //generator output current in per unit
+VT=Vr+X*I //genertor terminal voltage in per unit
+Ireal=1 //generator real output current in per unit
+Iimag=-0.3287 //Generator imaginary output voltage in per unit
+Vreal=1.0723 //generator real terminal voltage in per unit
+Vimag=0.220 //Generator imaginary terminal voltage
+Ei=VT+(%i*Xq)*I //Steady state angle of internal voltage in per unitge
+del=52.1*%pi/180
+Vdq=[sin(del) -cos(del);cos(del) sin(del)]*[Vreal;Vimag]; //d-q reference voltage
+Idq=[sin(del) -cos(del);cos(del) sin(del)]*[Ireal;Iimag]; //d-q reference current
+Eqs=Vdq(2)+Xdt*Idq(1) //Quadrature axis transient voltage
+Eds=Vdq(1)-Xqt*Idq(2) //Direct axis transient voltage
+Efd=Eqs+(Xd-Xdt)*Idq(1) //field voltage
+
+printf('The generator output current is %.4f%.4fi per unit\n',real(I),imag(I));
+printf('The genertor terminal voltage is %.4f+%.4fi per unit\n',real(VT),imag(VT));
+printf('The magnitude of Steady state angle of internal voltage in per unit is %.4f and its angle is %.4f degrees\n',abs(Ei),atand(imag(Ei),real(Ei)));
+disp(Vdq,'The d-q reference voltage in per unit is');
+disp(Idq,'The d-q reference current in per unit is');
+printf('The Quadrature axis transient voltage is %.4f per unit\n',Eqs);
+printf('The Direct axis transient voltage is %.4f per unit\n',Eds);
+printf('The field voltage is %.4f per unit\n',Efd);
+
+
+
+
+