diff options
Diffstat (limited to '3843/CH7/EX7.7/Ex7_7.sce')
-rw-r--r-- | 3843/CH7/EX7.7/Ex7_7.sce | 41 |
1 files changed, 41 insertions, 0 deletions
diff --git a/3843/CH7/EX7.7/Ex7_7.sce b/3843/CH7/EX7.7/Ex7_7.sce new file mode 100644 index 000000000..df5f45043 --- /dev/null +++ b/3843/CH7/EX7.7/Ex7_7.sce @@ -0,0 +1,41 @@ +// Example 7_7
+clc;funcprot(0);
+// Given data
+P_1=1*10^6;// Pa
+T_1=300+273;// K
+P_2=0.1*10^6;// Pa
+P_3=0.01*10^6;// Pa
+T_0=25+273;// K
+rho=1000;// kg/m^3
+
+// Calculation
+// From steam tables
+h_1=3051.2;// kJ/kg
+s_1=7.1237;// kJ/kg.K
+s_2=s_1;// kJ/kg.K
+// At P=0.1 MPa,
+x_2=0.96;// The quality of steam at state 2
+h_2=2587.3;// kJ/kg
+s_3=s_2;// kJ/kg.K
+// At P=0.01 MPa,
+x_3=0.86;// The quality of steam at state 3
+h_3=2256.9;// kJ/kg
+// The dead state for water is liquid at 25°C and 100 kPa
+h_f=104.9;// kJ/kg
+h_0=h_f;// kJ/kg
+s_f=0.3672;// kJ/kg.K
+s_0=s_f;// kJ/kg.K
+m_1=1;// kg
+m_2=0.10;// kg
+m_3=m_1-(10/100);// kg
+m_4=0.10;// kg
+s_4=0.6491;// kJ/kg
+h_4=191.8;// kJ/kg
+h_6=192.8;// kJ/kg
+X_2=m_2*[h_2-h_0-(T_0*(s_2-s_0))];// The availability at state 2 in kJ
+W_turb=(m_1*(h_1-h_2))+(m_3*(h_2-h_3));// kJ
+X_4=m_4*[h_4-h_0-(T_0*(s_4-s_0))];// The availability at state 4 in kJ
+W_pump=m_1*((P_1/10^3)-(P_2/10^3))/rho;// kJ
+Q_boil=m_1*(h_1-h_6);// kJ
+e_II=(X_2+W_turb)/(X_4+W_pump+([1-(T_0/T_1)]*Q_boil));// The second law effectiveness
+printf("\nThe second law effectiveness,e_II=%0.2f",e_II);
|