summaryrefslogtreecommitdiff
path: root/3830/CH1/EX1.19/Ex1_19.sce
diff options
context:
space:
mode:
Diffstat (limited to '3830/CH1/EX1.19/Ex1_19.sce')
-rw-r--r--3830/CH1/EX1.19/Ex1_19.sce32
1 files changed, 32 insertions, 0 deletions
diff --git a/3830/CH1/EX1.19/Ex1_19.sce b/3830/CH1/EX1.19/Ex1_19.sce
new file mode 100644
index 000000000..5cece7809
--- /dev/null
+++ b/3830/CH1/EX1.19/Ex1_19.sce
@@ -0,0 +1,32 @@
+// Exa 1.19
+
+clc;
+clear;
+
+// Given
+
+// Design of thermocouple voltmeter
+// Three ranges
+V1 = 5; // Volts
+V2 = 10; // Volts
+V3 = 25; // Volts
+Ifs = 50*10^-3; // Amp
+Rm = 200; // Ohms
+Imax = 5*10^-3; // Amps
+Rheater = 200; // Ohms
+
+// Solution
+
+printf(' To get a FSD for 5,10 and 25V, current through the heater must be limited to 5mA \n');
+
+printf('For a 5V range \n');
+Rs1 = V1/Imax - Rm;
+printf('Series resistance Rs = %d Ohms \n',Rs1);
+printf('For a 10V range \n');
+Rs2 = V2/Imax - Rm;
+printf('Series resistance Rs = %d Ohms \n',Rs2);
+printf('For a 25V range \n');
+Rs3 = V3/Imax - Rm;
+printf('Series resistance Rs = %d Ohms \n',Rs3);
+
+//The answer provided in the textbook for Rs3 is wrong