+clc;
+P=20000; // rated power of transformer
+E1=2500; // primary side voltage
+E2=500; // secondary side voltage
+r1=8; // primary resistance in ohm
+x1=17; // primary leakage reactance in ohm
+r2=0.3; // secondary resistance in ohm
+x2=0.7; // secondary leakage reactane in ohm
+k=E2/E1; // turns ratio
+re2=r2+r1*k^2; // equivalent resistance referred to secondary winding
+xe2=x2+x1*k^2; // equivalent leakage reactance referred to secondary winding
+Il=P/E2; // full load secondary current
+disp('case a');
+pf=0.8; // lagging power factor
+vd=Il*(re2*pf+xe2*sqrt(1-pf^2)); // Voltage drop in impedance in volts
+vt=E2-vd; // secondary terminal voltage
+printf('secondary terminal voltage for a lagging power factor is %f v\n',vt);
+vr=((E2-vt)/E2)*100; // voltage regulation
+printf('voltage regulation for a lagging power factor is %f percent\n',vr);
+disp('case b');
+pf=0.8; // leading power factor
+vd=Il*(re2*pf-xe2*sqrt(1-pf^2)); // Voltage drop in impedance in volts
+vt=E2-vd; // secondary terminal voltage
+printf('secondary terminal voltage for a leading power factor is %f v\n',vt);
+vr=((E2-vt)/E2)*100; // voltage regulation
+printf('voltage regulation for a leading power factor is %f percent\n',vr);