@@ -0,0 +1,40 @@
+//Fluid Systems - By - Shiv Kumar
+//Chapter 11- Centrifugal Pumps
+//Example 11.21
+//To Find the Manometric Efficiency
+ clc
+ clear
+
+//Given Data:-
+ n=4; //Number of Pumps
+ N=400; //Speed, rpm
+ H_Tm=40; //Total Manometric Head, m
+ Q=0.2; //Discharge, m^3/s
+ beta_o=40; //Vane Angle at Outlet, degrees
+ Do=600; //Diameter of the Impeller at Outlet, mm
+ bo=50; //Width of Impeller at outlet, mm
+
+
+//Data Used: -
+ rho=1000; //Density of water, kg/m^3
+ g=9.81; //Acceleration due to gravity, m/s^2
+
+
+//Computations:-
+ Do=Do/1000; //m
+ bo=bo/1000; //m
+ A=%pi*Do*bo; //Area of Flow, m^2
+ Hm=H_Tm/n; //Manometric Head of each Pump, m
+
+ uo=%pi*Do*N/60; //Tangential Velocity of Impeller at Outlet, m/s
+ Vfo=Q/A; //Velocity of Flow, m/s
+ Vfi= Vfo;
+ Vwo=uo-Vfo/tand(beta_o); //m/s
+
+ eta_man=g*Hm/(Vwo*uo)*100; //Manometric Efficiency in Percentage
+
+
+//Results:-
+ printf("Manometric Efficiency, eta_man=%.2f Percent \n",eta_man) //The answer vary due to round off error
+
+