diff options
Diffstat (limited to '3733/CH17/EX17.6/Ex17_6.sce')
-rw-r--r-- | 3733/CH17/EX17.6/Ex17_6.sce | 29 |
1 files changed, 29 insertions, 0 deletions
diff --git a/3733/CH17/EX17.6/Ex17_6.sce b/3733/CH17/EX17.6/Ex17_6.sce new file mode 100644 index 000000000..13c165989 --- /dev/null +++ b/3733/CH17/EX17.6/Ex17_6.sce @@ -0,0 +1,29 @@ +// Example 17_6
+clc;funcprot(0);
+//Given data
+m_a=84;// kg/hr
+p_v=70;// cm of Hg
+p_b=76;// cm of Hg
+T_i=20;// The temperature at the inlet of the vacuum pump in °C
+n_v=80;// Volumetric efficiency in %
+N=200;// rpm
+LbyD=3/2;// L/D ratio
+R=287;// J/kg.k
+
+//Calculation
+//(a)
+p_t=((p_b-p_v)/p_b)*1.013;// bar
+//From steam table, a saturation temperature at 20°C
+p_s=0.0238;// bar
+v_s=57.63;//The specific volume of saturated steam in m^3/kg
+p_a=p_t-p_s;// Partial pressure of air at point A in bar
+V=(m_a*R*(T_i+273))/(p_a*10^5);// Total volume in m^3/hr
+
+//(b)
+D=(((V/60)*100^2*100*4)/(%pi*1.5*N*(n_v/100)))^(1/3);// cm
+L=1.5*D;// Stroke of air pump in cm
+
+//(c)
+m_s=V/v_s;// kg/hr
+printf('\n(a)Capacity of air pump=%0.1f m^3/hr \n(bThe dimensions of the reciprocating air pump D=%0.0f cm & L=%0.1f cm \n(c)The mass of water vapour extracted per minute=%0.2f kg/hr',V,D,L,m_s);
+// The answer vary due to round off error
|