@@ -0,0 +1,40 @@
+//Chapter 6:Induction Motor Drives
+//Example 17
+clc;
+
+//Variable Initialization
+
+//Ratings of the star connected Induction motor
+f=50 // frequency in HZ
+Vl=440 //line voltage in V
+P=6 // number of poles
+Ns=120*f/P //synchronous speed
+
+//Parameters referred to the stator
+Xr_=1.2 // rotor winding reactance in ohm
+Xs=Xr_ // stator winding reactance in ohm
+Rr_=0.4 // resistance of the rotor windings in ohm
+Rs=0.5 // resistance of the stator windings in ohm
+Xm=50 // magnetizing reatance
+a=3.5 // stator to rotor turns ratio
+delta=0 // duty ratio at the given breakdown torque
+Sm=1 // slip at standstill
+
+//Solution
+
+//Slip at maximum torque without an external resistance is Sm=Rr_/sqrt(Rs**2+(Xs+Xr_)**2)
+//When an external resistanc Re referred to the stator is connected
+x=Sm*sqrt(Rs**2+(Xs+Xr_)**2) //x=Re+Rr_
+Re=x-Rr_
+y=0.5*a**2*(1-delta) // y=0.5*a**2*R*(1-delta) //y=Re
+R=Re/y
+
+//(Ns-N)/Ns
+//(Ns/Ns)-(N/Ns)
+Sm=(Ns/Ns)-(1/Ns)
+c=(x*Sm-Rr_)/(0.5*a**2*R) //c=(1-delta)
+delta=1-c //given duty ratio
+
+//Results
+mprintf("Variation of the duty ratio is:%.3f*N*10**(-3)",delta*1000)
+mprintf("\nHence the duty ratio must change linearly with speed N")