summaryrefslogtreecommitdiff
path: root/3731/CH6/EX6.13/Ex6_13.sce
diff options
context:
space:
mode:
Diffstat (limited to '3731/CH6/EX6.13/Ex6_13.sce')
-rw-r--r--3731/CH6/EX6.13/Ex6_13.sce30
1 files changed, 30 insertions, 0 deletions
diff --git a/3731/CH6/EX6.13/Ex6_13.sce b/3731/CH6/EX6.13/Ex6_13.sce
new file mode 100644
index 000000000..e2b1a1b86
--- /dev/null
+++ b/3731/CH6/EX6.13/Ex6_13.sce
@@ -0,0 +1,30 @@
+//Chapter 6:Induction Motor Drives
+//Example 13
+clc;
+
+//Variable Initialization
+
+//Ratings of the star connected Induction motor are same as that of Ex-6.9
+f=50 // frequency in HZ
+Vl=400 //line voltage in V
+P=4 // number of poles
+N=1370 //rated speed
+
+//Parameters referred to the stator
+Xr_=3.5 // rotor winding reactance in ohm
+Xs=Xr_ // stator winding reactance in ohm
+Rr_=3 // resistance of the rotor windings in ohm
+Rs=2 // resistance of the stator windings in ohm
+
+//Solution
+Wms=4*%pi*f/P
+f1=60 //frequency in Hz during speed control of the motor
+K=f1/f //the value of K at 60Hz
+x=Rs+sqrt(Rs**2+K**2*(Xs+Xr_)**2)
+Tmax_=3/(2*K*Wms)*(Vl/sqrt(3))**2/x //torque at 60 Hz frequency
+z=Rs+sqrt(Rs**2+(Xs+Xr_)**2)
+Tmax=3/(2*Wms)*(Vl/sqrt(3))**2/z //maximum torque
+ratio=Tmax_/Tmax //ratio
+
+//Result
+mprintf("Ratio of Motor breakdown torque at 60Hz to rated torque at 50Hz is:%.3f",ratio)