diff --git a/3681/CH15/EX15.4/Ex15_4.sce b/3681/CH15/EX15.4/Ex15_4.sce new file mode 100644 index 000000000..9d6fbb645 --- /dev/null +++ b/3681/CH15/EX15.4/Ex15_4.sce @@ -0,0 +1,26 @@ +// Calculating the winding depth and winding space and space factor and the number of turns
+clc;
+disp('Example 15.4, Page No. = 15.9')
+// Given Data
+hf = 80;// in between flanges (in mm)
+Do = 75;// in flange diameter (in mm)
+Di = 30;// in gross diameter tube (in mm)
+a = 0.0357;// Area of copper wire
+d = 0.213;// Diameter of bare conductor (in mm)
+d1 = 0.213+2*0.05;// Diameter of insulated conductor (in mm)
+// Calculation of the winding depth and winding space and space factor and the number of turns
+df = (Do-Di)/2;// Winding depth (in mm)
+Aw = hf*10^(-3)*df*10^(-3);// Winding space
+disp(df,'(a) Winding depth =');
+disp(Aw,' Winding space =');
+disp('(b) for conductors when they bed')
+Sf = 0.9*(d/d1)^(2);// Space factor
+T = Sf*Aw/a*10^(6);// Number of turns
+disp(Sf,' Space factor =');
+disp(T,' Number of turns =');
+disp(' for conductors when they do not bed')
+Sf = 0.78*(d/d1)^(2);// Space factor
+T = Sf*Aw/a*10^(6);// Number of turns
+disp(Sf,' Space factor =');
+disp(T,' Number of turns =');
+//in book answers are 22.5 mm, 0.0018 mm square, 0.417, 21025, 0.361 and 18200. The answers vary due to round off error
|