diff --git a/3574/CH5/EX5.6/EX5_6.png b/3574/CH5/EX5.6/EX5_6.png Binary files differnew file mode 100644 index 000000000..307395ae7 --- /dev/null +++ b/3574/CH5/EX5.6/EX5_6.png diff --git a/3574/CH5/EX5.6/EX5_6.sce b/3574/CH5/EX5.6/EX5_6.sce new file mode 100644 index 000000000..7fe573b8d --- /dev/null +++ b/3574/CH5/EX5.6/EX5_6.sce @@ -0,0 +1,36 @@ +// Example 5.6
+// Determine (a) New operating speed if a system disturbance causes a 10% drop
+// in voltage and 6% drop in frequency (b) New shaft horsepower.
+// Page No. 190
+
+clc;
+clear;
+close;
+
+// Given data
+etaV=0.90; // Efficiency related to voltage
+V=230; // Voltage
+etaF=0.94; // Efficiency related to voltage
+f=60; // Frequency
+N=6; // Number of poles
+nr1=1175; // Speed of motor
+P=20; // Horsepower of motor
+
+// (a) New operating speed if a system disturbance causes a 10% drop in
+// voltage and 6% drop in frequency
+V2=etaV*V; // New voltage after 10% drop
+f2=etaF*f; // New frequency after 6% drop
+ns1=120*f/N;
+ns2=120*0.94*f/N;
+s1=(ns1-nr1)/ns1; // Speed difference
+
+s2=s1*((V/V2)^2)*(f2/f);
+nr2=ns2*(1-s2); // New speed
+
+// (b) New shaft horsepower
+P2=P*(nr2/nr1); // With a constant torque load T2=T1
+
+// Display result on command window
+printf("\n New operating speed in case of voltage and frequency drop = %0.0f r/min ",nr2);
+printf("\n New shaft horsepower = %0.1f hp ",P2);
+
|