diff --git a/3574/CH12/EX12.2/EX12_2.sce b/3574/CH12/EX12.2/EX12_2.sce new file mode 100644 index 000000000..389460811 --- /dev/null +++ b/3574/CH12/EX12.2/EX12_2.sce @@ -0,0 +1,41 @@ +// Example 12.2
+// Computation of (a) No load voltage (b) Voltage regulation
+// (c) Resistance setting of rheostat necessary to obtain rated voltage
+// at rated conditions
+// Page No. 487
+
+clc;
+clear;
+close;
+
+// Given data
+P=300000; // Shunt generator power rating
+VT=240; // Shunt generator voltage rating
+Ra=0.00234; // Armature winding resistance
+RIP=0.00080; // Resistance of interpole winding
+Fnet=5100; // Net mmf
+Vnl=255; // No load voltage
+Vrated=240; // Rated voltage
+Nf=1020; // Turns per pole
+Vf=120; // Source that separately excites the generator
+If=5.69;
+Rf=18.1;
+
+// (a) No load voltage
+Ia=P/VT; // Armature current
+Ea=VT+Ia*(Ra+RIP); // Armature emf
+Ff=Fnet/(1-0.121);
+
+
+// (b) Voltage regulation
+VR=(Vnl-Vrated)*100/Vrated;
+
+// (c) Resistance setting of rheostat necessary to obtain rated voltage at rated conditions
+If=Ff/Nf;
+Rrheo=(Vf/If)-Rf; // Rheostat setting
+
+
+// Display result on command window
+printf("\n No load voltage = %0.0f V ",Vnl);
+printf("\n Voltage regulation = %0.2f Percent ",VR);
+printf("\n Resistance setting of rheostat necessary = %0.0f Ohm",Rrheo);
|