+// Exa 1.3a
+
+clc;
+clear all;
+
+Sv=1000; //voltmeter sensitivity(ohm/V)
+Vt=80; //Voltage across unknown resistance (V)
+It=10; //Current through unknown resistance (mA)
+Scale=150; //Volts
+
+//solution
+
+//Neglecting milliammeter resistance
+Rt=Vt/It; //Total circuit resistance(K ohm)
+Rv=Sv*Scale/1000; //Voltmeter resistance(K ohm/V)
+Rx=Rt*Rv/(Rv-Rt); //actual value of unknown resistance(K ohm)
+err=(Rx-Rt)/Rx *100;
+printf('Apparent value of resistance = %d K ohm \n Actual value of resistance = %.2f K ohm \n Percentage error = %.1f percent \n',Rt,Rx,err);
+disp("");
+
+// Exa 1.3b
+
+Sv=1000; //voltmeter sensitivity(ohm/V)
+Vt=30; //Voltage across unknown resistance (V)
+It=600; //Current through unknown resistance (mA)
+Scale=150; //Volts
+
+//solution
+
+//Neglecting milliammeter resistance
+Rt=Vt/(It*10^-3); //Total circuit resistance(ohm)
+Rv=Sv*Scale; //Voltmeter resistance(ohm/V)
+Rx=Rt*Rv/(Rv-Rt); //actual value of unknown resistance(ohm)
+err=(Rx-Rt)/Rx *100;
+printf('Apparent value of resistance = %d ohm \n Actual value of resistance = %.3f ohm \n Percentage error = %.3f \n',Rt,Rx,err);
+disp("In Example1.3a, a well calibrated voltmeter may give a misleading resistance when connected across two points in a high resistance circuit.")
+disp("The same voltmeter, when connected in a low resistance circuit(Examole 1.3b) may give a more dependable reading. This shows that voltmeters have a loading effect in the circuit during measurement.");
+// In the 1.3b example, the answer mentioned in the textbook for Rx and percent error is isncorrect.
+