summaryrefslogtreecommitdiff
path: root/3511/CH6/EX6.20/Ex6_20.sce
diff options
context:
space:
mode:
Diffstat (limited to '3511/CH6/EX6.20/Ex6_20.sce')
-rw-r--r--3511/CH6/EX6.20/Ex6_20.sce29
1 files changed, 29 insertions, 0 deletions
diff --git a/3511/CH6/EX6.20/Ex6_20.sce b/3511/CH6/EX6.20/Ex6_20.sce
new file mode 100644
index 000000000..97c6a8cc1
--- /dev/null
+++ b/3511/CH6/EX6.20/Ex6_20.sce
@@ -0,0 +1,29 @@
+clc;
+rp=2; // Pressure ratio
+T01=15+273; // Inlet temperature in kelvin
+p01=1; // Inlet pressure in bar
+T05=700+273; // Temperature at state 5 in kelvin
+T07=T05;
+eff_c=0.85; // compressor efficiency
+eff_T=0.85; // Turbine efficiency
+eff=0.5; // Effectiveness of heat exchanger
+Cp=1.147;// Specific heat at constant pressure in kJ/kg K
+rg=1.33;// Specific heat ratio of fuel
+r=1.4; // Specific heat ratio of air
+
+T03=T01;
+// p02/p01=p04/p03=rp
+//p04/p01=p05/p08=rp^2
+T_02=T01*(rp)^((r-1)/r);
+T02=T01+(T_02-T01)/eff_c;
+T04=T02;
+T_06=T05/rp^((rg-1)/rg);
+T06=T05-eff_T*(T05-T_06);
+T08=T06;
+T09=T04+eff*(T08-T04);
+WN=Cp*(T07-T08);
+Q=Cp*(2*T05-T06-T09);
+eff_th=WN/Q;
+
+disp ("kJ/kg",WN,"Net work done = ");
+disp ("%",eff_th*100,"The overall efficiency = ");