+clc;
+p1=1; // Pressure at state 1 in bar
+T1=300; // Temperature at state 1 in kelvin
+p4=5; // Pressure at state 4 in bar
+T5=1250; // Temperature at state 5 in kelvin
+Cp=1.005; // Specific heat at constant pressure in kJ/kg K
+r=1.4; // Specific heat ratio
+
+rp=p4/p1; // pressure ratio
+p2=sqrt (rp); // Because of perfect intercooling
+c1=p2^((r-1)/r);
+T2=T1*c1; // Temperature at state 2
+T4=T2; T3=T1;
+
+Wc1=Cp*(T2-T1); // Work of compressor 1
+Wc=2*Wc1; // net work of compressor
+WT1=Wc;
+T6=T5-(WT1/Cp); // Temperature at state 6
+p5_p6=(T5/T6)^(r/(r-1)); // Pressure ratio
+p6=rp/p5_p6; // Pressure at state 6
+p7=p1; T7=T5;p8=p6;
+T8=T7*(p7/p8)^((r-1)/r); // Temperature in state 8
+WT2=Cp*(T7-T8); // Turbine 2 work
+q=Cp*(T5-T4)+Cp*(T7-T6); // Heat supplied
+eff=WT2/q; // Efficiency of the cycle
+// With regenerator
+T9=T8;
+q_withregen=Cp*((T5-T9)+(T7-T6)); // Heat supplied with regenerator
+eff_withregen=WT2/q_withregen; // Efficiency of the cycle with regenerator
+I_eff=(eff_withregen-eff)/eff_withregen; // Percentage improvement in efficiency
+
+disp ("%",eff*100,"Efficiency of the cycle = ","kJ/kg",q,"Heat supplied = ","kJ/kg",WT2,"Work of turbine = ","(i). Without regenerator ");
+disp ("%",eff_withregen*100,"Efficiency of the cycle = ","kJ/kg (roundoff error)",q_withregen,"Heat supplied = ","(ii). With regenerator" );
+
+disp ("%",I_eff*100,"Percentage improvement in efficiency = ");