+// A Texbook on POWER SYSTEM ENGINEERING
+// A.Chakrabarti, M.L.Soni, P.V.Gupta, U.S.Bhatnagar
+// DHANPAT RAI & Co.
+// SECOND EDITION
+
+// PART IV : UTILIZATION AND TRACTION
+// CHAPTER 1: INDUSTRIAL APPLICATIONS OF ELECTRIC MOTORS
+
+// EXAMPLE : 1.4 :
+// Page number 681-682
+clear ; clc ; close ; // Clear the work space and console
+
+// Given data
+hp = 30.0 // Power of cage IM(hp)
+V = 500.0 // Cage IM voltage(V)
+P = 4.0 // Number of poles
+f = 50.0 // Frequency(Hz)
+I_fl = 33.0 // Full load current(A)
+s = 4.0/100 // Slip
+Z = 3.5 // Impedance per phase(ohm)
+tap = 60.0 // Auto-transformer tap setting(%)
+
+// Calculations
+// Case(1)
+I_s_1 = 3**0.5*(V/Z) // Starting current taken from line(A)
+N_s = 120*f/P // Speed(rpm)
+N_fl = N_s-N_s*s // Full load speed of motor(rpm)
+T_fl = hp*746*60/(2*%pi*N_fl) // Full load torque(N-m)
+T_s_1 = (I_s_1/I_fl)**2*s*T_fl // Starting torque(N-m)
+// Case(2)
+V_ph = V/3**0.5 // Phase voltage in star(V)
+I_s_2 = V_ph/Z // Starting current(A/phase)
+T_s_2 = (I_s_2/(I_fl/3**0.5))**2*s*T_fl // Starting torque(N-m)
+// Case(3)
+V_ph_at = V*tap/(3**0.5*100) // Phase voltage of auto-transformer secondary(V)
+V_impressed = V_ph_at*3**0.5 // Volatage impressed on delta-connected stator(V)
+I_s_3 = V_impressed/Z // Starting current(A/phase)
+I_s_line = 3**0.5*I_s_3 // Motor starting line current from auto-transformer secondary(A)
+I_s_line_3 = tap/100*I_s_line // Starting current taken from supply(A)
+T_s_3 = (I_s_3/(I_fl/3**0.5))**2*s*T_fl // Starting torque(N-m)
+// Case(4)
+I_s_4 = 3**0.5*V/Z // Starting current from line(A)
+T_s_4 = T_fl*s*(I_s_4/I_fl)**2 // Starting torque(N-m)
+
+// Results
+disp("PART IV - EXAMPLE : 1.4 : SOLUTION :-")
+printf("\nCase(1): Starting torque for direct switching, T_s = %.f N-m", T_s_1)
+printf("\n Starting current taken from supply line for direct switching, I_s = %.f A", I_s_1)
+printf("\nCase(2): Starting torque for star-delta starting, T_s = %.f N-m", T_s_2)
+printf("\n Starting current taken from supply line for star-delta starting, I_s = %.1f A per phase", I_s_2)
+printf("\nCase(3): Starting torque for auto-transformer starting, T_s = %.f N-m", T_s_3)
+printf("\n Starting current taken from supply line for auto-transformer starting, I_s = %.f A", I_s_line_3)
+printf("\nCase(4): Starting torque for series-parallel switch, T_s = %.f N-m", T_s_4)
+printf("\n Starting current taken from supply line for series-parallel switch, I_s = %.f A\n", I_s_4)
+printf("\nNOTE: ERROR: Calculation mistakes and more approximation in textbook solution")