diff --git a/3472/CH25/EX25.2/Example25_2.sce b/3472/CH25/EX25.2/Example25_2.sce new file mode 100644 index 000000000..b736b34c0 --- /dev/null +++ b/3472/CH25/EX25.2/Example25_2.sce @@ -0,0 +1,34 @@ +// A Texbook on POWER SYSTEM ENGINEERING
+// A.Chakrabarti, M.L.Soni, P.V.Gupta, U.S.Bhatnagar
+// DHANPAT RAI & Co.
+// SECOND EDITION
+
+// PART II : TRANSMISSION AND DISTRIBUTION
+// CHAPTER 18: POWER DISTRIBUTION SYSTEMS
+
+// EXAMPLE : 18.2 :
+// Page number 437-438
+clear ; clc ; close ; // Clear the work space and console
+
+// Given data
+I = 600.0 // Constant current drawn(A)
+D = 8.0 // Distance b/w two sub-stations(km)
+V_A = 575.0 // Potential at point A(V)
+V_B = 590.0 // Potential at point B(V)
+R = 0.04 // Track resistance(ohm/km)
+
+// Calculations
+x = poly(0,'x') // x(km)
+I_A = ((-V_B+R*I*D+V_A)-(R*I)*x)/(D*R) // Simplifying
+V_P = V_A-I_A*R*x // Potential at P in terms of x(V)
+dVP_dx = derivat(V_P) // dV_P/dx
+x_sol = roots(dVP_dx) // Value of x(km)
+I_A_1 = ((-V_B+R*I*D+V_A)-(R*I)*x_sol)/(D*R) // Current drawn from end A(A)
+I_B = I-I_A_1 // Current drawn from end B(A)
+
+// Results
+disp("PART II - EXAMPLE : 18.2 : SOLUTION :-")
+printf("\nPoint of minimum potential along the track, x = %.2f km", x_sol)
+printf("\nCurrent supplied by station A, I_A = %.f A", I_A_1)
+printf("\nCurrent supplied by station B, I_B = %.f A \n", I_B)
+printf("\nNOTE: ERROR: Calculation mistake in the textbook solution")
|