diff --git a/3472/CH24/EX24.3/Example24_3.sce b/3472/CH24/EX24.3/Example24_3.sce new file mode 100644 index 000000000..96520138e --- /dev/null +++ b/3472/CH24/EX24.3/Example24_3.sce @@ -0,0 +1,23 @@ +// A Texbook on POWER SYSTEM ENGINEERING
+// A.Chakrabarti, M.L.Soni, P.V.Gupta, U.S.Bhatnagar
+// DHANPAT RAI & Co.
+// SECOND EDITION
+
+// PART II : TRANSMISSION AND DISTRIBUTION
+// CHAPTER 17: ELECTRIC POWER SUPPLY SYSTEMS
+
+// EXAMPLE : 17.3 :
+// Page number 424
+clear ; clc ; close ; // Clear the work space and console
+
+// Given data
+PF = 0.95 // Lagging power factor
+
+// Calculations
+P_1 = 1.0 // Power in terms of V*I_1
+P_2 = 2.0*PF**2 // Power in terms of V*I_1
+P_additional_percentage = (P_2-P_1)/P_1*100 // Percentage additional power transmitted in a 3-phase 3-wire system
+
+// Results
+disp("PART II - EXAMPLE : 17.3 : SOLUTION :-")
+printf("\nPercentage additional power transmitted in a 3-phase 3-wire system = %.f percent", P_additional_percentage)
|