summaryrefslogtreecommitdiff
path: root/3472/CH24/EX24.3/Example24_3.sce
diff options
context:
space:
mode:
Diffstat (limited to '3472/CH24/EX24.3/Example24_3.sce')
-rw-r--r--3472/CH24/EX24.3/Example24_3.sce23
1 files changed, 23 insertions, 0 deletions
diff --git a/3472/CH24/EX24.3/Example24_3.sce b/3472/CH24/EX24.3/Example24_3.sce
new file mode 100644
index 000000000..96520138e
--- /dev/null
+++ b/3472/CH24/EX24.3/Example24_3.sce
@@ -0,0 +1,23 @@
+// A Texbook on POWER SYSTEM ENGINEERING
+// A.Chakrabarti, M.L.Soni, P.V.Gupta, U.S.Bhatnagar
+// DHANPAT RAI & Co.
+// SECOND EDITION
+
+// PART II : TRANSMISSION AND DISTRIBUTION
+// CHAPTER 17: ELECTRIC POWER SUPPLY SYSTEMS
+
+// EXAMPLE : 17.3 :
+// Page number 424
+clear ; clc ; close ; // Clear the work space and console
+
+// Given data
+PF = 0.95 // Lagging power factor
+
+// Calculations
+P_1 = 1.0 // Power in terms of V*I_1
+P_2 = 2.0*PF**2 // Power in terms of V*I_1
+P_additional_percentage = (P_2-P_1)/P_1*100 // Percentage additional power transmitted in a 3-phase 3-wire system
+
+// Results
+disp("PART II - EXAMPLE : 17.3 : SOLUTION :-")
+printf("\nPercentage additional power transmitted in a 3-phase 3-wire system = %.f percent", P_additional_percentage)