+// FUNDAMENTALS OF ELECTICAL MACHINES
+// M.A.SALAM
+// NAROSA PUBLISHING HOUSE
+// SECOND EDITION
+
+// Chapter 3 : TRANSFORMER AND PER UNIT SYSTEM
+// Example : 3.7
+clc;clear; // clears the console and command history
+
+// Given data
+V_1 = 200 // primary voltage of transformer in V
+V_2 = 400 // secondary voltage of transformer in V
+R_1 = 0.3 // primary resistance in Ω
+X_1 = 0.6 // primary reactance in Ω
+R_2 = 0.8 // secondary resistance in Ω
+X_2 = 1.6 // secondary reactance in Ω
+I_2 = 10 // secondary supply current in A
+cos_phi2 = 0.8 // power factor lagging
+
+// caclulations
+a = V_1/V_2 // turn ratio
+phi2 = acosd(0.8)
+sin_phi2 = sind(phi2)
+R_02 = R_2+(R_1/a^2) // total resistance referred to secondary side Ω
+X_02 = X_2+(X_1/a^2) // total reactance referred to secondary side Ω
+E_2 = (V_2*cos_phi2+I_2*R_02)+(%i*(V_2*sin_phi2+I_2*X_02)) // no-load voltage
+V_r = (abs(E_2)-V_2)/V_2*100 // voltage regulation
+
+// display the result
+disp("Example 3.7 solution");
+printf(" \n Voltage regulation \n V_r = %.0f percent \n", V_r);
+
+